Description
:
6 kW
(FA 6000FC and FA 6000FS ) in the whole 87.5 ÷ 108 MHz band.
COLD FET™ technology. This revolutionary technology,
a ITEL international patent, is used in the FA series amplifiers
to optimize the input matching of MOS-FET transistors in order to obtain
broadband amplification stages without any RF component with a typical
RF efficiency > 80 %. This means:
- lower heating
- higher devices safety
- higher total reliability
- low AC power consumption
Extraordinary RF efficiency: the COLD-FET™ technology
allows to obtain from the amplifiers the full power rating reducing
of almost 20% the devices recommended operating DC voltage and current.
Uninterrupted service. A proportional foldback protection
circuit reduces the output power without any on-air interruption, keeping
the devices always within the safety conditions in case of:
- load mismatching
- environmental over-temperature
- cooling failure
- failure in one or more amplification modules
- failure in power supply modules.
High modules redundancy: each 1 kW plug-in module is
composed of 4 x 300 W stages coupled with high isolation combiners and
independent power supply. This architecture assures the highest module
redundancy.
High system redundancy: after the plug-in module redundancy
starts the great system redundancy realized through the coupling system
that permits to the amplifier to work at reduced power even in case
of module failure.
On-air serviceable. The 1 kW modules replacement can
be made without turning-off the amplifier.
High gain 18 dB gain permits the full output power
with low input driving.
Broadband : no adjustments are required for the full
power operation in the 87.5÷108 MHz band.
The automatic power control circuit adjusts and stabilizes
with precision (±2%) the maximum output power in the whole band.
Switch-mode power supply. High efficiency (> 85
%) and oversized power supply modules grant low heating, low AC power
consumption and superior reliability.
Low overheating. The high cooling system efficiency
limits at only +10 °C the heatsink overheating respect to the environmental
temperature. This permits the service even in overheated sites.
Low consumption. The high overall efficiency means
a reduction of AC power consumption and operating costs.
Reduced maintenance. Easy accessibility of all parts,
no RF failure, no power supply failure, external serviceable air filter
reduce dramatically the maintenance costs.
Metering. A complete metering system placed on the
front panel permits the precise reading of: all currents and voltages
of each MOS-FET stage, forward power, reflected power.
Remote control. It is available as option a remote
control interface for the following parameters: voltages and currents
of each RF stage, forward power, reflected power, alarms status, on/off,
stand-by.
Meets or exceeds international standards for safety